2 general data and operating conditions, Regenerative power supply modules – Lenze 9400 Manual User Manual
Page 263
Regenerative power supply modules
General data and operating conditions
7
263
EDS94SPP101-7.1
7.2
General data and operating conditions
General data
Conformity and approval
Conformity
CE
2006/95/EG
Low-Voltage Directive
Approval
UL
UL 508C
In preparation:
Industrial Control Equipment, File No. 132659
Mains data
Mains types
With earthed
point
Unrestricted use
The measures described for IT
systems must be observed
and carried out in all systems
(TN, TT and IT) and for all
interconnected modules
( 294)!
IT systems
Unrestricted use
Noise emission
EN 61800-3
With E94AZMR0xx4SDB mains filter: 6 x 10 m, C2
With E94AZMR0xx4LDB mains filter: 10 x 50 m, C2
Radiation: category C3
Noise immunity (according to requirements of EN 61800-3)
Electrostatic discharge
(ESD)
EN 61000-4-2
8 kV for air discharge,
4 kV for contact discharge to housing
Radio frequency
Conducted
EN 61000-4-6
150 kHz ... 80 MHz, 10 V/m 80% AM (1kHz)
Interference (housing) EN 61000-4-3
80 MHz ... 1000 MHz, 10 V/m 80% AM (1kHz)
Protection of persons and device protection
Enclosure
EN 60529
IP 20
Not in the wire range of
the terminals on the
motor side
NEMA 250
Protection against contact to
type 1
Insulation resistance
EN 61800-5-1
Overvoltage category III
Derating at and above 2000 m AMSL: overvoltage category II
Isolation of control circuits EN 61800-5-1
Safe mains isolation through double/reinforced insulation.
Short-circuit strength
EN 61800-5-1
DC-bus connection: not short-circuit-proof
Brake resistor connection: full
Control connections: full
Discharge current
EN 61800-5-1
> 3.5 mA
Observe regulations and
safety instructions!
Cyclic mains switching
Cyclic mains switching of five times in five minutes is fully
permissible.