Single-axis controllers – Lenze 9400 Manual User Manual
Page 51
Single-axis controllers
Rated data (devices for 400/500V mains)
Operation at rated mains voltage 230 V
4
51
EDS94SPP101 EN 7.1
Output currents [A] at switching frequency
2 kHz
4 kHz
8 kHz
16 kHz
4)
Type
I
aN2
I
aM2
I
aN4
I
aM4
I
aN8
I
aM8
I
aN16
E94ASxE0024
1.9
3)
6.0
1.9
3)
6.0
1.5
4.8
1.1
E94ASxE0034
3.1
3)
10.0
3.1
3)
10.0
2.5
8.0
1.9
E94ASxE0044
5.0
3)
16.0
5.0
3)
16.0
4.0
12.8
3.0
E94ASxE0074
8.8
3)
21.0
8.8
3)
21.0
7.0
16.8
5.3
E94ASxE0134
16.3
3)
39.0
16.3
3)
39.0
13.0
31.2
9.8
E94ASxE0174
20.6
3)
49.5
20.6
3)
49.5
16.5
39.6
12.4
E94ASxE0244
29.4
3)
58.8
29.4
3)
58.8
23.5
47.0
17.6
E94ASxE0324
38.4
76.8
38.4
76.8
32.0
64.0
16.8
E94ASxE0474
47.0
94.0
47.0
94.0
41.0
82.0
21.5
E94ASxE0594
59.0
118
59.0
118
41.0
82.0
21.5
E94ASxE0864
86.0
172
86.0
172
73.0
146
38.3
E94ASxE1044
104
208
104
208
78.0
156
40.9
I
aN2
Rated value of permanent output current at a frequency of ≥ 0 Hz
I
aM2
Maximum output current (overload current) at frequency ≥ 0 Hz
z
Periodic load change of 0.5 s with I
aM2
and recovery time of 4.5 s with
75 % I
aN2
I
aN4
, I
aN8,
I
aN16
Rated value of continuous output current at a frequency of ≥ 5 Hz
(reduce to 0.66 * I
aNx
for 0 ... 5 Hz)
I
aM4
, I
aM8
Maximum output current (overload current) at frequency ≥ 5 Hz
(reduce to 0.66 * I
aMx
for 0 ... 5 Hz)
z
Periodic load change of 0.5 s with I
aMx
and recovery time of 4.5 s with
75 % I
aNx
z
Can be achieved using the setting ”x kHz fixed” in C00018
bold
Nominal value I
aN
3)
Operation with permanent currents > I
aN8
requires an external mains choke.