Accessories (overview), Rated data – Lenze 9400 Manual User Manual
Page 431
Accessories (overview)
Motor holding brake control modules
Motor holding brake control module E94AZHY0101
9
431
EDS94SPP101 EN 7.1
Rated data
Voltage
Frequency
Current [A]
Number of
phases
[V]
[Hz]
max. +45 °C c
max. +55 °C c
E94AZHY0101
24
0 (DC)
0.3 ... 5
0.3 ... 5
2
c
Temperature in the control cabinet
Voltage
Frequency
Current [A]
Number of
phases
[V]
[Hz]
max. +45 °C c
max. +55 °C c
E94AZHY0101
24
0 (DC)
0.3 ... 5
0.3 ... 5
2
c
Temperature in the control cabinet
Area
Values
Input voltage
DC 24 V (18 ... 30 V)
Output voltage
Corresponds to input voltage
Brake current
0.3 ... 5 A
Switching capacity
Max. 110 W
Breaking energy
Max. 10 Ws
Cable protection
Recommendation: 7.5 A, tripping characteristic ”B” or ”C”
Control input
Control voltage
Internal
Control current
Protective function
Maximum cable length
In the chapter ”Electrical installation” the dependency of the cable length on
the brake current and the cable cross-section is described.
Operating frequency
Max. 6/min
Operating times
Can be ignored compared to the delay time of the brake.
See documentation of the brake.
Service life
> 10 millions of cycles
Protection against
Overload
No
Short circuit of the
terminals
Yes
Polarity reversal at the
input
Yes
Insulation
1)
Double insulation (EN61800-5-1: V
rated
= 300 V AC),
Separation (UL: V
rated
= 500 V AC)
1)
Brake connection against control card of the controller