Accessories (overview), Connection of the motor holding brake, Terminal data control connection – Lenze 9400 Manual User Manual
Page 458
Accessories (overview)
Motor holding brake control modules
Motor holding brake control module E94AZHN0026
9
458
EDS94SPP101 EN 7.1
Connection of the motor holding brake
Terminal X107
Labelling
Description
Connection of the motor holding brake:
BD1
BD2
+ (Lenze: WH)
- (Lenze: BN)
E94AZHN0026: 180 V DC, max. 0.75 A
Ensure correct polarity!
L1
L2/N
Supply voltage of the motor holding brake
SSP94A6107
Terminal data
Conductor cross-section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb-in]
Flexible
0.5 ... 2.5
20 ... 12
Spring terminal
With wire end
ferrule
Stripping length or contact length: 8 mm
Terminal data
Control connection
Terminal X117
Labelling
Description
DI
Digital input
GI
GND digital in
DO
Signalling output
24V
24-V supply by safely separated power supply unit (SELV/PELV)
SSP94A6117
GND
GND digital out
Terminal data
Conductor cross-section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb-in]
Flexible
0.5 ... 2.5
20 ... 12
Spring terminal
With wire end
ferrule
Stripping length or contact length: 8 mm
Digital output DO
State
Description
HIGH
No fault
LOW
Fault
z
Supply voltage of the motor holding brake is missing
z
Motor holding brake is not connected
z
Brake cable is defective
– Open circuit
– Short circuit
z
Supply voltage of the motor brake control is missing