Accessories (overview), Rated data – Lenze 9400 Manual User Manual
Page 454
Accessories (overview)
Motor holding brake control modules
Motor holding brake control module E94AZHN0026
9
454
EDS94SPP101 EN 7.1
Environmental conditions
Climate
Storage
IEC/EN 60721-3-1
1K3 (-25 ... +60 °C)
Transport
IEC/EN 60721-3-2
2K3 (-25 ... +70 °C)
Operation
IEC/EN 60721-3-3
3K3 (-10 ... +55 °C)
Site altitude
0 ... 4000 m amsl
1000 ... 4000 m amsl: current derating of 5 %/1000 m
Pollution
EN 61800-5-1
Pollution degree 2
Vibration resistance
(9.81 m/s
2
= 1 g)
Transport
IEC/EN 60721-3-2
2M2
EN 61800-2
2 ... 9 Hz: amplitude 3.5 mm
10 ... 200 Hz: acceleration resistant up to 10 m/s
2
200 ... 500 Hz: acceleration resistant up to 15 m/s
2
Operation
Germanischer Lloyd
5 ... 13.2 Hz: amplitude ±1 mm
13.2 ... 100 Hz: acceleration resistant up to 0.7 g
EN 600068-2-6
10 ... 57 Hz: amplitude 0.075 mm
57 ... 150 Hz: acceleration resistant up to 10 m/s
2
Rated data
Voltage
Frequency
Current [A]
Number of
phases
[V]
[Hz]
max. +45 °C c
max. +55 °C c
E94AZHN0026
400/500
50/60
0.75/0.75
0.61/0.61
1
c
Temperature in the control cabinet
Voltage
Frequency
Current [A]
Number of
phases
[V]
[Hz]
max. +45 °C c
max. +55 °C c
E94AZHN0026
180/225
0 (DC)
0.75/0.75
0.61/0.61
1
c
Temperature in the control cabinet
Area
Values
Input voltage
AC 400 V (320 ... 550 V), 45 ... 65 Hz
Output voltage
DC 180 V
With mains voltage of AC 400 V
Brake current
0.1 ... 0.61 A
Cable protection
Recommendation: 5 A, tripping characteristic ”B” or ”C”
Control input DI
Signalling output DO
Control voltage
DC 24 V, PLC level
HIGH
LOW
DC +15 ... 30 V
DC 0 ... +3 V
Control current
Input 5 ... 10 mA
Output 5 ... 50 mA
Protective function
Protected against polarity reversal up to DC 60 V
Max. connectable cable
cross-section
2.5 mm
2
AWG 12
Maximum cable length
150 m