9 - 36

IP

N 07

4-

54

5-

P1

E

Cygnus 2 Operating Manual

7

(0x07)

Status Message

Designators

Message

Word>

8 bytes

1-13

(Can have

12 DAC

recorders)

|

....

Status Message Word

corresponding to one of

the status messages,

as encoded in the SG 6

command.

This indicates which status message designators are to be returned. Note that only one bit may

be set, that is, only the designators for one error can be requested per command.Returns a string
of bytes. First byte is the number of bytes following. The following bytes indicate the designators

for the requested status message.If there are no designators, the first byte returned will be zero.

9

(0x09)

Transient

Messages

1

See encodes in

section

13.4 on page 13-6

.

10

(0x0a)

Sensor Status

6


One byte for each

Sensor Range between

0 and 5.

0 = Good Crystal and active. 1 = Failed Crystal and active. 2 = Invalid Measurement on Crystal

and active. 3 = Good Crystal and inactive. 4 = Failed Crystal and inactive.

5 = Invalid Measurement on Crystal and inactive.

11

(0x0b)

Timer Status

Timer Number

1 - 20

1

Response:0 = Timer

inactive1 = Timer active

12

(0x0c)

Timer Value

Timer Number

1 - 20

4

Response is in tenths of

seconds. Max Time =

99:59:59.0 (3599990

tenths of seconds)

13

(0x0d)

Counter Value

Counter
Number

1 - 20

4

14

(0x0e)

Thickness Sum

Equation

number

0 - 3

4 or 12

or

0 = All thickness

equations

1 - 3 = the number of

the equation to return.

15

(0x0f)

Get date

12

Integers for month, day,

year or day, month

year, depending on

date format general

parameter.

Table 9-12 Status general commands (continued)

SG

Comm
and ID

Description

Option

Number

of bytes

in the

response

Data Returned

Notes