25 update logic statement, 26 cygnus 2 event list – INFICON Cygnus 2 Thin Film Deposition Controller User Manual
Page 177

9 - 29
IP
N 07
4-
54
5-
P1
E
Cygnus 2 Operating Manual
9.4.25 Update Logic Statement
Command = UL
Statement Number =
Length of logic elements =
statement, including the 0x03 (ETX) terminator.
Set of elements = See description in QL above.
Example: IF External Input 21 and External Input 2 and External Input 18 and
External Input 8
THEN Start Timer 1 and Extern Out On 10
Hex code for above including length and checksum:
1500554C01114115264102264112264108205101410A031A
Response = None (Just header and trailer)
Logic changes are not allowed while a process is running or if the Cygnus 2 is in a
stop.
9.4.26 Cygnus 2 Event List
Events used in the Logic Statement IF section. Logic codes are used in the
remote communication query and update commands. The Logic codes start at
0x41 because there are formatting codes (for connectors, parentheses, etc.)
used in the logic statements that are ASCII codes below 0x41. See
.
Table 9-10 Event list
Events
1st
numeric
(1 Byte)
(XXX)
Min Max
2nd
numeric
(Integer)
(YYY)
Min
Max
Logic
Code
Logic
Code
Negated
Parenthesis
External Input
Input #
1
28
0x41
0xBF
Pre-Deposit
0x42
0xBE
In Deposit
0x43
0xBD
Post-Deposit
0x44
0xBC
Non Deposit
0x45
0xBB
Ready
0x46
0xBA
Crucible Switch
0x47
0xB9
PreCond Rise
0x48
0xB8