beautypg.com

INFICON Cygnus 2 Thin Film Deposition Controller User Manual

Page 182

background image

9 - 34

IP

N 07

4-

54

5-

P1

E

Cygnus 2 Operating Manual

* PreCond S/H Off XXX

Material #

0

6

0x54

* PreCond S/H On XXX

0x55

* Soak 1 Hold Off XXX

0x56

* Soak 1 Hold On XXX

0x57

* Soak 2 Hold Off XXX

0x58

* Soak 2 Hold On XXX

0x59

* Clock Hold Off

0x5A

* Clock Hold On

0x5B

* Start Inhbt Off **

0x5C

* Start Inhbt On **

0x5D

* Xtl Fl Inhbt Off

Sensor #

0

6

0x5E

* Xtl Fl Inhibt On

0x5F

* RWS Inhibit Off XXX

(RWS = RateWatcher Sample)

Material #

0

6

0x60

* RWS Inhibit On XXX

0x61

* RWS Init(iate) Off XXX

0x62

* RWS Initiate On XXX

0x63

Message On XXX See Note

Message #

1

10

0x64

Message Off XXX See Note

0x65

Note: There are ten User Messages available for the user to
construct. These messages can be displayed and cleared via logic
actions. User Messages are constructed on the General page
Message screen.

Note: * = Remote Comm and Logic will be independent. Methods
used to set action must be used to clear action.
** = Start Inhibit will carry through a power cycle

Table 9-11 Action list (continued)

Actions

Numeric

(Byte)

Min Max

Logic

Code