ETC Element v2.1.0 User Manual
Page 58
46
Element User Manual
• {MSC Transmit Channel} [5] [0] [Enter]
{ACN - MIDI Tx ID}
This setting allows you to specify the ID number of MIDI Show Control data that the console
transmits over an Architecture for Control Network (ACN). When set, the console will transmit MSC
data to any gateway that has its “ACN MIDI Tx ID” set to the same number. ACN MIDI Tx ID can be
from 1-32. When using the local MIDI ports on Gio, Ion, or Element, this setting needs to match the
MIDI Tx Group ID in the ECU>{Settings}>{Local I/O}>Show Control Gateway>Group IDs. For
example:
• {ACN MIDI Tx ID} [2][5] [Enter]
{String MIDI TX}
When enabled, this setting will cause the console to send serial strings instead of a MIDI Show
Control message when certain actions happen at the console.
{MIDI Cue List}
MIDI Cue List specifies the cue list that the console will use to send MSC data. If left blank and MSC
Tx is enabled, all cue lists will generate MSC events. Otherwise, only the particular list (or lists)
selected will fire MSC events.
{Analog Inputs}
This is a master setting for receiving analog inputs from a Net3 I/O Gateway or the local analog
ports on a Gio, Ion, or Element. When disabled it will turn off all analog input for all event lists.
Default is “Enabled”.
{Relay Outputs}
This is a master setting for triggering external relays from a Net3 I/O Gateway or the local ports on
a Gio, Ion, or Element. When disabled it will turn off all external relays for all event lists. The default
is “Enabled”.
{String RX}
This setting will enable receiving strings on all Serial RX formats.
{String RX Group IDs}
This button is for setting up which Serial Port Group ID (from I/O Gateway settings in GCE) the
console will listen to. This only affects serial traffic from I/O gateways, not network UDP messages
or ACN strings. Group IDs are from 1-32. Remember group IDs relate to the number set in the
gateway. It can be set to listen to multiple group IDs by using [Thru] and [+].
{String RX Port}
This setting specifies the UDP port that the console will listen to for receiving strings.
{String TX}
This settings will enable sending strings on all Serial TX formats.
{String TX Group IDs}
This button is for setting up which Serial Port Group ID (from I/O Gateway settings in GCE) the
console will send to. This only affects serial traffic to I/O gateways, not network UDP messages or
ACN strings.Group IDs are from 1-32. Remember group IDs relate to the number set in the
gateway. It can be set to send to multiple group IDs by using [Thru] and [+].
{String TX Port}
Setting for the UDP destination port that the console will send strings.
{String TX IP Address}
Sets the destination IP address that the console will send strings.