beautypg.com

Selective storing cues using [record – ETC Element v2.1.0 User Manual

Page 120

background image

108

Element User Manual

[selected channels] {Color} [Record] [Record] [4] [Enter] - stores only the manual

color data for the selected channels into cue 4. Values for other channels/parameters will track
in from the previous cue.

Selective Storing Cues using [Record]

Cues can also be created using selective storing, which allows you to specify only the channels and
or parameters that you want to store. When using a selective store, you must specify the channel
list to be included or excluded, identified by [Thru], [+], [-], as part of the [Record] command.

The following examples illustrate various methods of selectively storing cues:

[1] [Thru] [3] [Record] [2] [Enter] - records the selected channels 1 through 3 to cue

2.

[-] [9] [Record] [5] [Enter] - records cue 5 while excluding channel 9.

Since Element is a tracking console, any channels not included in the selective store, but that do
have values in the previous cue will track into the recorded cue. This is true even when the desk is
in Cue Only mode. To remove intensity values that would otherwise track when on a selective store,
the rem dim command can be used.

See “Remainder Dim” on page 93.