8. Messages
427
KAPL12150-W
An error occurred during internal processing of HDLM Performance
Monitor. HDLM Performance Monitor cannot start. Details =
aa...aa
Details
An attempt to start HDLM Performance Monitor has failed.
There might not be enough memory or the host might be under a heavy load.
This message might also be output when the WMI repository is corrupted.
aa...aa: Error details (character string)
Action
Check the system status.
If this message is output repeatedly, contact your HDLM vendor or the
maintenance company if there is a maintenance contract for HDLM.
If the WMI repository is corrupted, consider rebuilding the repository.
KAPL12151-W
A Windows Management Instrumentation service access error
occurred. Details =
aa...aa
,
bb...bb
Details
A Windows Management Instrumentation service access error occurred.
The Windows Management Instrumentation service might not be working.
This message might also be output when the WMI repository is corrupted.
aa...aa: API name (character string)
bb...bb: Error code (decimal (base-10) number)
Action
Check whether the Windows Management Instrumentation service is working. If
not, start it. If the service cannot be started or if the problem is not solved even
after restarting the service, contact your HDLM vendor or the maintenance
company if there is a maintenance contract for HDLM.
If the WMI repository is corrupted, consider rebuilding the repository.
KAPL12152-W
An error occurred during internal processing of HDLM Performance
Monitor. Details =
aa...aa
,
bb...bb
Details
During Performance Monitor processing, an error occurred that was probably not
a result of a user operation.