6. Command Reference

234

after the next time an automatic failback is successful. Because the errors and

elapsed time are not counted or measured while intermittent errors are not

being monitored, the values will not change.

The monitoring interval specified in this parameter is stored even though

specifying

-iem

off

disables intermittent error monitoring. Therefore,

when you re-enable intermittent error monitoring and a monitoring interval

is not specified, error monitoring will be performed by using the stored

monitoring interval.

-iemnum

number-of-times-error-is-to-occur

Specify the number of times the error is to occur. Valid values are from 1 to

99. The default is

3

.

During intermittent error monitoring, if you change the number of times that

the error is to occur in order for the system to determine that an intermittent

error has occurred, the number of errors and the time that has passed since

intermittent error monitoring has started are reset to 0. The changed setting

will take effect immediately and intermittent error monitoring will restart.
When intermittent error monitoring is not being performed, if you change the

number of times that the error is to occur in order for the system to determine

that an intermittent error has occurred, the new value will take effect after the

next automatic failback successfully completes. When intermittent error

monitoring is not being performed, the number of errors that determine that

an intermittent error has occurred is not counted and this value is not

changed.

The number of times that the error is to occur is stored in the system, even

when

-iem off

is specified and intermittent error monitoring is disabled.

Therefore, when you re-enable intermittent error monitoring without

specifying the number of times, the error monitoring will be executed using

the value stored in the system.

When the

set

-iem

on

operation is executed during error monitoring, even if you

do not change the conditions for intermittent error monitoring, the number of

errors and the time that has passed since the error monitoring has started are reset

to 0. Intermittent error monitoring will then resume with the changed settings.

If you set the automatic failback function to

off

while intermittent error

monitoring is

on

, intermittent error monitoring will be disabled. Note, however,