HP Hitachi Dynamic Link Manager Software User Manual
Page 240

6. Command Reference
216
sure that you use the
view
operation to find the current AutoPATH_ID of the
target path, before executing the
offline
operation.
Example
The following example shows how to place offline all the paths connected to
the channel adapter port
0A
. In this example, a path whose AutoPATH_ID is
000001
is connected to the target channel adapter port:
>dlnkmgr offline -cha -pathid 000001
KAPL01055-I All the paths which pass the specified CHA
port will be changed to the Offline(C) status. Is this
OK? [y/n]:y
KAPL01056-I If you are sure that there would be no problem
when all the paths which pass the specified CHA port are
placed in the Offline(C) status, enter y. Otherwise,
enter n. [y/n]: y
KAPL01061-I 2 path(s) were successfully placed
Offline(C); 0 path(s) were not. Operation name = offline
>
-pathid
AutoPATH_ID
Use this parameter to place a single path offline.
Specify the current AutoPATH_ID of the target path, which is displayed by using
the
view
operation. For details about the
view
operation, see 6.7 view (Displays
Information). Leading zeros can be omitted (
000001
and
1
indicate the same
AutoPATH_ID); however, when the target AutoPATH_ID is
000000
, enter
000000
or
0
for the parameter value.
AutoPATH_IDs are re-assigned every time the host is restarted. Always make
sure that you use the
view
operation to find the current AutoPATH_ID of the
target path, before executing the
offline
operation.
-hbaportwwn
HBA-port-WWN
[-tid
target-ID
-hlun
host-LU-number]
Use this parameter to place offline all paths connected to the HBA port indicated
by the specified HBA port WWN. If niether the
-tid
parameter nor the
-hlun
parameter are specified, all paths that pass through the specified HBA port WWN
will be placed offline. Only one set of values can be specified for the
-hbaportwwn
parameter.
For HBA-port-WWN, specify the value of
HBAPortWWN
. The parameter is not
case sensitive.
For target-ID, specify the target ID portion of
PathName
. Leading zeroes can be
omitted from the target ID (
0000000000000001
and
1
are the same value). The
parameter is not case sensitive.