HP Hitachi Dynamic Link Manager Software User Manual
Page 175

3. Creating an HDLM Environment
151
By specifying both the trace file size and the number of trace files, you can collect up
to 1024000KB of trace data.
• Setting up the number of trace files by using the
set
operation
The following is an example of setting up the number of trace files by using a
command:
>dlnkmgr set -systfn 10
Specify the number of trace files by using numbers.
(12) Setting Up Audit Log Data Collection
If you want to collect audit log data, you must also specify the collection level for audit
log data and the audit log categories.
Table 3-18: Values Indicating Audit Log Data Collection Levels describes the values
that indicate audit log data collection levels. An audit log data collection level is a
severity level. The default is
6
.
Table 3-18: Values Indicating Audit Log Data Collection Levels
Table 3-19: Values Indicating Audit Log Data Categories describes the values that
indicate audit log data categories. The default is
all
.
Table 3-19: Values Indicating Audit Log Data Categories
Value (severity)
Explanation
0
Error-level audit log data is collected.
1
2
3
4
Error-level and Warning-level audit log data is collected.
5
6
Error-level, Warning-level, and Information-level audit log data
is collected.
7
Value
Explanation
ss
Audit log events of the
StartStop
category are collected.
c
Audit log events of the
Authentication
category are collected.