beautypg.com

HP Hitachi Dynamic Link Manager Software User Manual

Page 175

background image

3. Creating an HDLM Environment

151

By specifying both the trace file size and the number of trace files, you can collect up

to 1024000KB of trace data.

Setting up the number of trace files by using the

set

operation

The following is an example of setting up the number of trace files by using a

command:


>dlnkmgr set -systfn 10

Specify the number of trace files by using numbers.

(12) Setting Up Audit Log Data Collection

If you want to collect audit log data, you must also specify the collection level for audit

log data and the audit log categories.
Table 3-18: Values Indicating Audit Log Data Collection Levels describes the values

that indicate audit log data collection levels. An audit log data collection level is a

severity level. The default is

6

.

Table 3-18: Values Indicating Audit Log Data Collection Levels

Table 3-19: Values Indicating Audit Log Data Categories describes the values that

indicate audit log data categories. The default is

all

.

Table 3-19: Values Indicating Audit Log Data Categories

Value (severity)

Explanation

0

Error-level audit log data is collected.

1

2

3

4

Error-level and Warning-level audit log data is collected.

5

6

Error-level, Warning-level, and Information-level audit log data
is collected.

7

Value

Explanation

ss

Audit log events of the

StartStop

category are collected.

c

Audit log events of the

Authentication

category are collected.