beautypg.com

HP Hitachi Dynamic Link Manager Software User Manual

Page 213

background image

4. HDLM Operation

189

Figure 4-1: Using the command to confirm that an LU has been added

5.

For the new LU, write a signature, create partitions, and then format it.

Note:

The PathID is determined by the system choosing the smallest, available number

that is not already in use for another path. For example, when a path is deleted and

then a new path is added, the PathID for the added path might not be the same

number as the deleted PathID.

When MSCS is used

1.

Add an LU.

2.

Stop node B.

3.

On node A, perform the steps shown in When MSCS is not used.

4.

Stop node A, and then start node B.

5.

On node B, perform the steps shown in When MSCS is not used.
When you create a partition, assign the same drive letter as the one assigned for

node A in step 3.

6.

Stop node B, and then restart node A.

7.

On node A, register the new LU in MSCS, and set it up.