6. Command Reference

233

occur is reached during the monitoring interval. A path that is assumed to have an

intermittent error is excluded from automatic failbacks. Intermittent error

monitoring is performed on each path. Intermittent error monitoring starts when

a path is recovered from an error by performing an automatic failback.
If you omit the intermittent error monitoring interval or the number of times that

the error is to occur, each setting is specified as follows:

When the intermittent error monitoring interval or the number of times that

the error is to occur has not been specified before:
The intermittent error monitoring interval is set to 30 minutes, and the

number of times that the error is to occur is set to 3.

When the intermittent error monitoring interval or the number of times that

the error is to occur has been specified before:
The values specified from the last time are used.

When a value of 2 or more is specified for the number of times, the following

condition must be satisfied:

error-monitoring-interval

>=

checking-interval-for-automatic-failback

x

number-of-times-error-is-to-occur-during-intermittent-error-monitoring

If this condition is not satisfied, the KAPL01080-W message will be output and

an error will occur. If this happens, change any of the following settings: the

checking interval for automatic failback, intermittent error monitoring interval, or

the number of times that the error is to occur.
When you set the number of times that the error is to occur to

1

, the above

condition does not need to be satisfied.
The following shows the sub-parameters that should be specified: the error

monitoring interval and the number of times that the error is to occur:

-intvl

error-monitoring-interval

Specify the monitoring interval for an intermittent error. Use a value from

1

to

1440

minutes. The default is

30

.

During intermittent error monitoring, if changes are made to the intermittent

error monitoring interval setting or the setting for the number of times that

an error is to occur, the error count and the elapsed time measured since

monitoring has started are reset to 0.
When intermittent error monitoring is not being performed, if changes are

made in the settings of the intermittent error monitoring interval or the

number of times that an error is to occur, the new settings will take effect