Monitoring and Managing the Switch
66
Edge Switch Element Manager User Guide
—
11 Unresponsive node connected to port.
Possible
causes are:
— Hardware problem on switch or on a connected node where ELP
frames are not delivered, the response is not received, or a fabric login
(FLOGI) cannot be received. There may be problems in the switch
SBAR.
— Faulty or dirty cable connection.
— Faulty host bus adapters that do not send out FLOGI within a
reasonable time frame.
—
0x0C ESA Security Mismatch.
Processing of Exchange Security
Attribute Frame detected required security feature mismatch.
—
0x0D Fabric Binding Mismatch.
Fabric Binding is enabled and
detected a switch connection with an incompatible fabric membership list.
Could also be the result of problems delivering EFMD ILS.
—
0x0E Authorization Failure Reject.
The switch on the
other side of the ISL detected a security violation. This switch receives
notification via a generic reject reason code and sets its port to the invalid
attachment state in sympathy.
—
0x0F Unauthorized Switch Binding WWN.
A Switch Binding
error was detected on either an E_Port or F_Port.
—
0x10 Authentication Failure.
ISL Authentication Check
(CHAP) failed. If you wish to allow the connection, update the
authentication lists or disable authentication.
—
0x11 Fabric Mode Mismatch
—A connection was not allowed
because:
— An HP M-Series switch or director attempted to connect to an HP
switch or director running in Open Fabric mode.
— An HP M-Series switch or director running in Open Fabric mode
attempted to connect to another vendor’s switch or director with an
incorrect ELP revision level.
—
0x12 CNT WAN Extension Mode Mismatch
—The ELP
maximum frame sizes were incompatible because one product running in
CNT WAN extension mode attempted to connect to another product
running in a normal mode.