Information and Error Messages
236
Error Messages
The following
parameters cannot be
disabled while
Enterprise Fabric Mode
is active: Insistent
Domain ID, Rerouting
Delay, Domain RSCNs.
You attempted to
disable these
parameters in the
Configure Switch
Parameters dialog box
while Enterprise Fabric
Mode is enabled.
Disable Enterprise Fabric Mode
through the Enterprise Fabric
Mode dialog box in HAFM,
then disable the parameters.
The link to the director
is not available.
The Ethernet
connection between
the HAFM appliance
and the director is
down or unavailable.
Establish and verify the network
connection.
The link to the switch is
not available.
The Ethernet
connection between
the HAFM appliance
and the switch is down
or unavailable.
Establish and verify the network
connection.
The IPL configuration
cannot be deleted.
Deletion of the IPL
address configuration
was attempted and
was not allowed.
Cancel the operation.
The management
server is busy
processing a request
from another Element
Manager.
The HAFM appliance
is processing a request
from another instance
of an Element
Manager, and cannot
perform the requested
operation.
Wait until the process is
completes, then perform the
operation again.
The optical transceiver
is not installed.
Information is not
available for a port
without an optical
transceiver installed.
Install an SFP optical transceiver
in the port.
The switch did not
accept the request.
The director or switch
cannot perform the
requested action.
Retry the operation. If the
condition persists, contact the
next level of support.
The maximum number
of address
configurations has
been reached.
The maximum number
of saved address
configurations has
been reached.
Delete configurations no longer
needed to allow new
configuration to be saved.
Table 8: Element Manager Messages (Continued)
Message
Description