Information and Error Messages

222

Error Messages

Control Unit Port (CUP)

name and port name

are identical (FICON

ONLY).

Within the address

configuration, one or

more of the port names

are the same as the

CUP name.

Make sure all names are

unique for the ports and CUP

name.

Date entered is invalid. The date is entered

incorrectly at the

Configure Date and

Time dialog box.

Individual field entries

may be correct, but the

overall date is invalid

(for example, a day

entry of 31 for a

30-day month).

Verify each entry is valid and

consistent.

Device applications

should be terminated

before starting

diagnostics. Press

NEXT to continue.

Port diagnostics

(loopback tests) cannot

be performed on a

port while an attached

device application is

running.

Terminate the device

application and perform

diagnostics again.

[device WWN] cannot

be removed from the

Switch Membership List

while participating in

Switch Binding. The

device must be isolated

from the switch, or

Switch Binding

deactivated before it

can be removed.

You attempted to

remove a device

WWN from the Switch

Membership List

(SANtegrity Binding

feature) while Switch

Binding is enabled.

Remove the device from the

switch by blocking the port,

setting the switch offline, or

disabling Switch Binding

through the Switch Binding

Change State dialog box before

removing devices from the

Switch Membership List.

Director clock alert

mode must be cleared

before enabling period

synchronization.

Clock alert mode is

enabled through the

Configure FICON

Management Server

dialog box and you

attempted to enable

Periodic Date/Time

Synchronization

through the Configure

Date and Time dialog

box.

Disable clock alert mode

through the Configure FICON

Management Server dialog

box.

Table 8: Element Manager Messages (Continued)

Message

Description

Action