Information and Error Messages
222
Error Messages
Control Unit Port (CUP)
name and port name
are identical (FICON
ONLY).
Within the address
configuration, one or
more of the port names
are the same as the
CUP name.
Make sure all names are
unique for the ports and CUP
name.
Date entered is invalid. The date is entered
incorrectly at the
Configure Date and
Time dialog box.
Individual field entries
may be correct, but the
overall date is invalid
(for example, a day
entry of 31 for a
30-day month).
Verify each entry is valid and
consistent.
Device applications
should be terminated
before starting
diagnostics. Press
NEXT to continue.
Port diagnostics
(loopback tests) cannot
be performed on a
port while an attached
device application is
running.
Terminate the device
application and perform
diagnostics again.
[device WWN] cannot
be removed from the
Switch Membership List
while participating in
Switch Binding. The
device must be isolated
from the switch, or
Switch Binding
deactivated before it
can be removed.
You attempted to
remove a device
WWN from the Switch
Membership List
(SANtegrity Binding
feature) while Switch
Binding is enabled.
Remove the device from the
switch by blocking the port,
setting the switch offline, or
disabling Switch Binding
through the Switch Binding
Change State dialog box before
removing devices from the
Switch Membership List.
Director clock alert
mode must be cleared
before enabling period
synchronization.
Clock alert mode is
enabled through the
Configure FICON
Management Server
dialog box and you
attempted to enable
Periodic Date/Time
Synchronization
through the Configure
Date and Time dialog
box.
Disable clock alert mode
through the Configure FICON
Management Server dialog
box.
Table 8: Element Manager Messages (Continued)
Message
Description
Action