HP StorageWorks 2.12 Edge Switch User Manual
Page 218
Information and Error Messages
218
Error Messages
Cannot run diagnostics
on a port that is failed.
Port diagnostics
(loopback tests) cannot
be performed on a
port that has failed any
previous diagnostic
(power-on diagnostic,
online diagnostic, or
loopback test). The
amber LED associated
with the port
illuminates to indicate
the failed state.
Reset the port and perform
diagnostics again.
Cannot run diagnostics
on an active E-port.
Port diagnostics cannot
be performed on an
active E-port.
Run diagnostics on an E-port
only when it is not active.
Cannot run diagnostics
on a port that is not
installed.
Port diagnostics cannot
be performed on a
port card that is not
installed.
Run diagnostics only on a port
that is installed.
Cannot run diagnostics
on a port card that is
not installed.
Port diagnostics
(loopback tests) cannot
be performed on a
port that does not have
a small form factor
(SFF) optical
transceiver installed.
Install a transceiver in the port
and perform diagnostics again.
Cannot run diagnostics
while a device is
logged-in to the port.
Port diagnostics
(internal loopback test)
cannot be performed
on a port while an
attached Fibre Channel
device is logged in.
Ensure the device is logged out
and perform diagnostics again.
Cannot run diagnostics
while a device is
logged-in to the port.
A device is logged in
to the port where a
diagnostic test is
attempted.
Log out the device and run the
diagnostic test again.
Cannot save IPL
configuration while
active=saved is
enabled.
You cannot save the IPL
file while the
active=saved property
is set.
The FICON Management
Server property, active=save,
must be disabled for HAFM to
save the IPL file.
Table 8: Element Manager Messages (Continued)
Message
Description
Action