beautypg.com

Phase jitter measurement, Press f6 (more), Press f3 (phase jitter on) – GW Instek GSP-830 User Manual User Manual

Page 89: Press f4 (phase jitter setup)

background image

POWER

MEASUREMENT

89

Phase Jitter Measurement

Background

Phase Jitter refers to the amount of phase fluctuation
that leads to shortening or lengthening the center
frequency.

Parameter Start

offset

Beginning frequency offset in reference to
the center frequency.
0kHz to ½ of span, 0.1MHz resolution

Stop

offset

End frequency offset in reference to the
center frequency.
0kHz to ½ of span, 0.1MHz resolution

1. Press the Measurement key.

Meas

1. Activate Phase

Jitter

2. Press F6 (More).

More

F 6

3. Press F3 (Phase Jitter On).

Phase Jitter

On Off

F 3

4. The display switches to Phase jitter mode, updating

Phase jitter result in the lower half of the display.

Phase
fluctuation
Time
fluctuation

2. Set start/stop

offset

1. Press F4 (Phase Jitter Setup).

Phase Jitter

Setup

F 4

2. Press F1 (Start Offset) and F2

(Stop Offset) to set the amount
of the beginning and end offset.

Start

Offset

F 1

Stop

Offset

F 2

3. Enter the offset using the

Numerical/Unit keys.
Range: 0kHz to ½ of span

BK SP

dB

Enter

GHz /

Sec

mSec

MHz /

kHz /

Sec

μ