Gsp-830 as slave (external reference signal) – GW Instek GSP-830 User Manual User Manual

Page 134

background image

GSP-830 User Manual

134

Internal reference signal, median stability.
Available when the ±1ppm stability module
(page174) is installed. The MED icon
appears at the bottom of the display.

Internal reference signal, high stability
(reserved for future use).

GSP-830 as slave (external reference signal)

Panel operation

1. Press the Option key.

Option

2. Press F4 (Ext Ref Freq) to

enable external reference signal.

Ext Ref Freq

10MHz

F 4

3. Use the Left/Right keys or

Scroll knob to select the
external reference frequency.

4. Connect the external reference

signal to the input terminal on
the rear panel.

5. The external reference signal

icon appears at the bottom of
the display.

Signal type

TTL signal

Frequency

10 preset frequencies are available (units in MHz).

1.0 1.544

2.048

5.0 10.0

10.24 13.0 15.36 15.4 19.2

Status check

1. Press the System key.

System

2. Press F6 (More).

More...

F 6

3. Press F4 (System Config On).

System Config

On Off

F 4

The system configuration window appears. The
External Reference Signal sign

shows the

status: - enabled, - disabled.