beautypg.com

Move the cursor using the arrow keys, Move the cursor to the target using the arrow keys, Press f6 (return) to go back to the previous menu – GW Instek GSP-830 User Manual User Manual

Page 54: Press f2 (correction on) to turn on the correction

background image

GSP-830 User Manual

54

3b. Modify

correction point

1. Move the cursor using the

Arrow keys.

2. Enter the new frequency or

gain using the Numerical keys
and Unit keys or dB key.

Pt. Freq. (MHz) Gain

1

2

3

4

5

2300

2.5

2400

2500

2600

2200

1.3

2.8

1.8

1.2

BK SP

dB

Enter

GHz /

Sec

mSec

MHz /

kHz /

Sec

μ

3c. Delete

correction point

1. Move the cursor to the target

using the Arrow keys.

2. Press F2 (Delete). The

frequency and gain are deleted
together.

Delete

F 2

3. To undo the last deletion,

press F4 (Undelete).

Undelete

F 4

Example: point 3 deleted

Pt.

Freq. (MHz)

Gain

1

2

3

4

5

2300

2.5

2400

2500

2600

2200

1.3

2.8

1.8

1.2

Pt.

Freq. (MHz)

Gain

1

2

3

4

5

2300

2.5

2500

2600

2200

1.3

1.8

1.2

4. Save correction

set

1. Press F5 (Save Now). The

edited data is saved internally.

Save Now

F 5

2. Press F6 (Return) to go back

to the previous menu.

Return

F 6

5. Activate

correction

1. Press F2 (Correction On) to

turn on the correction.

Correction

On Off

F 2

2. The amplitude icon appears at

the bottom of the display.

After correction

Frequency response becomes linear (original), and the
gain is compensated by +2 to +3dB.