195
•
Route-refresh
They have the same header.
Figure 71 BGP message header
•
Marker—The 16-byte field is used to delimit BGP messages. The Marker must be all ones.
•
Length—The 2-byte unsigned integer indicates the total length of the message.
•
Type—This 1-byte unsigned integer indicates the type code of the message. The following type
codes are defined: 1–Open, 2-Update, 3-Notification, 4–Keepalive, and 5–Route-refresh. The
former four are defined in RFC1771, and the last one is defined in RFC2918.
Open
After a TCP connection is established, the first message sent by each side is an Open message for peer
relationship establishment. An Open message contains the following fields:
Figure 72 BGP Open message format
•
Version—This 1-byte unsigned integer indicates the protocol version number. The current BGP
version is 4.
•
My autonomous system—This 2-byte unsigned integer indicates the Autonomous System number of
the sender.
•
Hold time—When establishing a peer relationship, two parties negotiate an identical hold time. If
no Keepalive or Update is received from a peer within the hold time, the BGP connection is
considered down.
•
BGP identifier—An IP address that identifies the BGP router.
•
Opt Parm Len (Optional Parameters Length)—Length of optional parameters, which is set to 0 if no
optional parameter is available.
•
Optional parameters—Used for multiprotocol extensions, and other functions.
- H3C SR6600-X H3C SR6600 H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSWM1WCM10 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module