Test Functions

Power Blazer

435

FEAC

Loopback Commands

Current displays the valid message received in the last second of
measurement. A valid message is detected only when receiving 10
consecutive occurrences of a specific Loopback Command
immediately followed by 10 occurrences of a specific Channel
Codeword
.

Previous displays the last valid message received excluding the