Test Setup - Test Configurator, Timer, and System
Power Blazer
247
Traces (SONET/SDH)
Note: 16-bytes selection allows typing up to 15 bytes (a CRC-7 byte will be added
in front for a total of 16 bytes). 64-bytes selection allows typing up to
62-bytes (
R
> and
F
> bytes will be added at the end for a total of
64-bytes). Traces values should be ASCII suitable characters including the
ITU T.50 Characters on page 31.
TIM-S/RS-TIM, TIM-P/HP-TIM, TIM-V/LP-TIM: Enables the
corresponding Trace Identifier Mismatch for the expected message
defined. These settings are coupled with the Result - Traces/Labels
configuration (refer to Traces - SONET/SDH on page 398).
Format: Allows the selection of the expected format:
16 Bytes (default), or 64 Bytes.
Expected: Allows entering the expected J0 trace message for
TIM-S/RS-TIM, J1 for TIM-P/HP-TIM, and J2 for TIM-V/LP-TIM. See
Default values/messages on page 246.
TCM Access Point Identifier
Note: Available when TCM is enabled from the Signal - Signal Configuration
STS/AU Path (N1), and VT/TU Path (Z6 or N1 (TU-3))
Enter the N1/Z6 value/message to be generated.
TC-TIM-P/HPTC-TIM/TC-TIM-V/LPTC-TIM: Enables the corresponding
TCM Access Point Identifier for the expected message defined. These
settings are coupled with the Traces configuration from Traces
(SONET/SDH) on page 246.
Copy RX allows to use the received TIM message as the expected one.