Link – EXFO FTB/IQS-88000 Series Power Blazer for FTB-2/2Pro/500/IQS-600 User Manual
Page 151

Test Setup - Test Configurator, Timer, and System
Power Blazer
139
Interface (Ethernet, Packet Sync, and Fibre Channel)
Interface (Ethernet, Packet Sync, and Fibre
Channel)
From the Test menu, tap Setup, Test Configurator, the interface block,
and the Interface tab.
LINK
A green/red arrow is used to indicate the status of the test link (at the PCS
level for parallel interfaces).
A green arrow indicates that the link is up.
A red arrow indicates alarms (at the PCS level for parallel
interfaces), the link is down.
For Ethernet and Packet Sync test applications:
For optical interfaces, the Local Fault Detected, Local Fault Received,
Remote Fault, LOA, Hi-BER, and/or WIS Link (10GE WAN) alarm
status are displayed. Refer to Ethernet on page 266 and Ethernet - PCS
Lanes on page 269 for more information.
Auto-Negotiation check box is available with 10/100/1000M Electrical
interface. When the Auto-Negotiation check box is selected the test
application indicates to the remote port which parameters to use. The
Auto-Negotiation check box is automatically selected for 1GE
Electrical interface and is not configurable.
Note: When the Auto-Negotiation check box is selected, the port Speed, Duplex,
Flow Control, and Local Clock parameters can be set. Those settings are
not applied immediately to the port, they are used only when the
negotiation process is started and take effect only when the
auto-negotiation succeeds. However current settings are applied
immediately to the port when the Auto-Negotiation check box is cleared.