beautypg.com

Physical interface - electrical – EXFO FTB/IQS-88000 Series Power Blazer for FTB-2/2Pro/500/IQS-600 User Manual

Page 213

background image

Test Setup - Test Configurator, Timer, and System

Power Blazer

201

Signal (Transport)

Physical Interface - Electrical

Note: The following settings are available with electrical signal and their

availability depend on the signal itself and its mapping. For optical
interface, see
Physical Interface - Optical on page 199.

LBO (Line Build Out): The LBO allows to meet the interface
requirements over the full range of cable lengths.

Signal

LBO

DS1

Preamplification values: DSX-1 (0-133 ft)

a

, DSX-1 (133-266 ft),

DSX-1 (266-399 ft), DSX-1 (399-533 ft), DSX-1 (533-655 ft),
Cable simulation (CSU Emulation mode) values: CSU (0.0 dB),
CSU (-7.5 dB), CSU (-15.0 dB), CSU (-22.5 dB).

a.

Default value

DS3

0 to 225 ft range

a

, 225 to 450 ft range, and Cable Simulation

900 ft.

E1/E3/E4

Not available

STS-1e/STM-0e 0 to 225 ft range

a

, 225 to 450 ft range, and Cable Simulation

900 ft).

STS-3e/STM-1e 0 to 225 ft range.