Test Functions

424

FTB/IQS-88000 Series

Client Offset

Max. Positive Offset (ppm) indicates the maximum positive
frequency offset between the standard rate specification and the rate
from the received signal.

Note: The following parameters are only available with ODUflex mapped to

pattern.

Frequency Offset Analysis check box, when selected, enables the
frequency offset measurements. This setting is enabled by default for
Coupled topology, and disabled for Through / Through Intrusive
topology.

Expected Frequency (GHz) is available when the Frequency Offset
Analysis
check box is selected.

For Coupled topology, the frequency is set to the configured TX Rate
(Refer to page 102).

For Through / Through Intrusive topology, enter the expected
frequency in GHz.