Test Results

260

FTB/IQS-88000 Series

Alarms/Errors

DS1

Alarms

AIS (Alarm Indication Signal)

RX: An unframed all-ones signal is received.

OOF (Out-OF-Frame)

RX: Four consecutive frame bit errors are detected.

RAI (Yellow) (Remote Alarm Indication)

RX:

SF framing: Bit 2 in each timeslot contains “0”.

ESF framing: Eight “ones” followed by eight “zeros” pattern is
received continuously in the data link (FDL).

Errors

Framing Bit

RX: An incorrect value appeared in a bit position reserved for framing.

CRC-6 (Cyclical Redundancy Check) is only available with ESF
framing.

RX: One or more bit errors have been detected in a block of data
through cyclical redundancy check.