EXFO FTB/IQS-88000 Series Power Blazer for FTB-2/2Pro/500/IQS-600 User Manual
Page 175

Test Setup - Test Configurator, Timer, and System
Power Blazer
163
Network
IP
IP Version allows the selection of either IPv4 (default) or IPv6. Only IPv4 is
supported for TCP Throughput test application.
For IPv4 the following configuration parameters are available.
Automatic IP (DHCP) check box, when selected (cleared by default),
allows to dynamically obtain an IP address from a DHCP (Dynamic
Host Configuration Protocol) server.
IP Address: Enter the IP address of the port. The default setting is
10.10.x.y, where x and y are respectively the two least significant bytes
of the port default MAC address. Not available when the Automatic IP
(DHCP) check box is selected.
Subnet Mask: Enter the Subnet Mask. The default setting is
255.255.000.000. Not available when the Automatic IP (DHCP) check
box is selected.
Default Gateway check box, when selected (cleared by default),
allows to enter a default Gateway IP address. When the Default
Gateway check box is selected, its default address is 0.0.0.0. The
Default Gateway address is not configurable when the Automatic IP
(DHCP) check box is selected.