EXFO FTB/IQS-88000 Series Power Blazer for FTB-2/2Pro/500/IQS-600 User Manual
Page 445

Test Functions
Power Blazer
433
FEAC
Amount is the amount of codeword to be generated: 1 to15
(default is 10).
Inject generates error(s) according to the Codeword and mode
selected.
Loopback Commands
Control
Codeword is the loopack control codeword to be generated: Line
Loopback Activate (00001110) - (Default) or Line Loopback
Deactivate (00111000).
Amount is the number of Control Codeword to be generated: 1 to
15 (default is 10).
Channel
Codeword is the channel codeword to be generated.
Amount is the number of Channel Codeword to be generated:
1 to 15 (Default is 10).
Inject generates the defined loopback command.
Channel Codeword
DS3 Line (00110110)
DS1 Line-No10 (01010100)
DS1 Line-No20 (01101000)
DS1 Line-No1 (01000010)
DS1 Line-No11 (01010110)
DS1 Line-No21 (01101010)
DS1 Line-No2 (01000100)
DS1 Line-No12 (01011000)
DS1 Line-No22 (01101100)
DS1 Line-No3 (01000110)
DS1 Line-No13 (01011010)
DS1 Line-No23 (01101110)
DS1 Line-No4 (01001000)
DS1 Line-No14 (01011100)
DS1 Line-No24 (01110000)
DS1 Line-No5 (01001010)
DS1 Line-No15 (01011110)
DS1 Line-No25 (01110010)
DS1 Line-No6 (01001100)
DS1 Line-No16 (01100000)
DS1 Line-No26 (01110100)
DS1 Line-No7 (01001110)
DS1 Line-No17 (01100010)
DS1 Line-No27 (01110110)
DS1 Line-No8 (01010000)
DS1 Line-No18 (01100100)
DS1 Line-No28 (01111000)
DS1 Line-No9 (01010010)
DS1 Line-No19 (01100110)
DS1 Line-All (00100110)