Test Functions

Power Blazer

433

FEAC

Amount is the amount of codeword to be generated: 1 to15
(default is 10).

Inject generates error(s) according to the Codeword and mode
selected.

Loopback Commands

Control

Codeword is the loopack control codeword to be generated: Line
Loopback Activate (00001110)
- (Default) or Line Loopback
Deactivate (00111000)
.

Amount is the number of Control Codeword to be generated: 1 to
15 (default is 10).

Channel

Codeword is the channel codeword to be generated.

Amount is the number of Channel Codeword to be generated:
1 to 15 (Default is 10).

Inject generates the defined loopback command.

Channel Codeword

DS3 Line (00110110)

DS1 Line-No10 (01010100)

DS1 Line-No20 (01101000)

DS1 Line-No1 (01000010)

DS1 Line-No11 (01010110)

DS1 Line-No21 (01101010)

DS1 Line-No2 (01000100)

DS1 Line-No12 (01011000)

DS1 Line-No22 (01101100)

DS1 Line-No3 (01000110)

DS1 Line-No13 (01011010)

DS1 Line-No23 (01101110)

DS1 Line-No4 (01001000)

DS1 Line-No14 (01011100)

DS1 Line-No24 (01110000)

DS1 Line-No5 (01001010)

DS1 Line-No15 (01011110)

DS1 Line-No25 (01110010)

DS1 Line-No6 (01001100)

DS1 Line-No16 (01100000)

DS1 Line-No26 (01110100)

DS1 Line-No7 (01001110)

DS1 Line-No17 (01100010)

DS1 Line-No27 (01110110)

DS1 Line-No8 (01010000)

DS1 Line-No18 (01100100)

DS1 Line-No28 (01111000)

DS1 Line-No9 (01010010)

DS1 Line-No19 (01100110)

DS1 Line-All (00100110)