S-oam and mpls-tp oam – EXFO FTB/IQS-88000 Series Power Blazer for FTB-2/2Pro/500/IQS-600 User Manual

Page 308

background image

Test Results

296

FTB/IQS-88000 Series

Alarms/Errors

S-OAM and MPLS-TP OAM

Alarms

Note: The following alarms are available when the CC Function check box is

selected (refer to page 183).

Loss Continuity

RX: No CCM frames with same or lower MEG/MD Level were received
from the peer MEP within an interval equal to 3.5 times the configured
CCM transmission period. The alarm is cleared when at least 3 CCM
frames with same or lower MEG/MD Level from the peer MEP are
received within an interval equal to 3.5 times the configured CCM
transmission period.

Mismerge

RX: A CCM frame was received from the peer MEP with same MEG/MD
Level but with incorrect MEG ID/MAID

1

value or format. The alarm is

cleared when no CCM frames with same MEG/MD Level but with
incorrect MEG ID/MAID

1

value or format are received within an interval

equal to 3.5 times the configured CCM transmission period.

Unexp MEG/MD Lvl (Unexpected MEG/MD Level)

RX: A CCM frames was received from the peer MEP with lower
MEG/MD Level. The alarm is cleared when no CCM frames with lower
MEG/MD Level are received within an interval equal to 3.5 times the
configured CCM transmission period.

1. The MAID, composed of a Domain ID and a Short MA Name strings, is incorrect if one or both strings are not as

expected.