Test Results
Power Blazer
371
Summary (Cable Test)
Wire Map Test Result gives the wire map test result for each pair.
When the link is up: The wire map result for each pair is given as seen
by the FTB/IQS-88000 Series to get a link up. This means that the wire
map result may not correspond to the type of cable tested depending
on the cable(s) used and/or the configuration of the cable mode (MDI,
MDIX, or auto-detection) on both the FTB/IQS-88000 Series and the far
end equipment. For example, two crossed pair cables end to end used
between the FTB/IQS-88000 Series and a far end equipment may give a
straight pair (MDI) wire map result.
Note: For 1Gbit/s, both MDI and MDIX can be reported simultaneously since
crossed pairs detection is performed independently for pairs A-B and C-D.
MDI
Straight pair.
MDIX
Crossed pair.
MDI (-)
For 1Gbit/s, straight pair with swapped wires within pair.
MDIX (-)
For 1Gbit/s, crossed pair with pair A swapped with pair B and/or pair
C swapped with pair D.
Noise
Excessive noise on a pair most likely caused by a link partner running
in 10/100 Mbit/s forced mode. In this case, no propagation delay or
length is reported and there is no comparison with any threshold.