Test Results

Power Blazer

391

Summary (TCP Throughput)

Summary (TCP Throughput)

From the Test menu, tap Results, and the Summary tab.

Test Status indicates the actual test status as follows.

“--”: The test is not running or results are not available.

In Progress: The test is running.

Completed: The test is completed, stopped at the planned time, or
manually stopped when there is no set timer.

Aborted - : The test is interrupted; stopped before the
set timer. Possible are: TCP Session Closed or Remote
IP Not Found
.

Start Time indicates the date and time the test has been started. The
date and time is reset every time the test is restarted or reset.

Test/Power Recovery: Test Recovery (Widows 8 or above) or
Power Recovery (Windows XP), when displayed, indicates that the
test has automatically recovered from a power failure. The number of
occurrences is also displayed next to the Test/Power Recovery field.
Refer to Power Failure Recovery on page 521.

Logger Full, when displayed, indicates that the logger is full. Refer to
Logger on page 328.

TCP Throughput

TCP Connection Status indicates the actual TCP connection status.

“--”: The test is not running or results are not available.

In Progress indicates that the TCP initialization algorithm is in
progress.

Waiting indicates on the remote unit that the test is started but the
TCP initialization algorithm is not initiated by the local unit.