beautypg.com

Far-end – EXFO FTB/IQS-88000 Series Power Blazer for FTB-2/2Pro/500/IQS-600 User Manual

Page 349

background image

Test Results

Power Blazer

337

Performance Monitoring

SEP (Severely Errored Period) (G.828 only): A sequence between
3 to 9 consecutive SES. The sequence is terminated by a second which
is not a SES.

SEPI (Severely Errored Period Intensity) (G.828 only): Gives the count
of SEP events in available time, divided by the total available time in
seconds.

Far-End

EFS (Error Free Second): Gives the count of the seconds within which
no error occurred or when a defect is detected on the near-end.

EC (Error Count) (G.821 only): Gives the number of bit errors.

EB (Errored Block) (G.826, G.828, and G.829): Gives the count of
blocks in which one or more bits are in error.

ES (Errored Second): For G.826, G.828, G.829, M.2100 ISM, and
M.2101: Gives the count of the seconds within which one or more
anomalies (FAS (DSn/PDH), EB, etc.) occurred or at least one defect
occurred.

SES (Severely Errored Second)

For G.826, G.828, G.829 and M.2101: Gives the number of seconds
within which anomalies (FAS (DSn/PDH), EB, etc.) are  X% (see table
below) or at least one defect occurred. X = 30% for DSn/PDH signals;
see the following table for SONET/SDH signals SES threshold.

OC-1

STS-1e

STM-0

STM-0e

OC-3

STS-3e

STM-1

STM-1e

OC-12

STM-4

OC-48

STM-16

OC-192

STM-64

OC-768

STM-256

Path

30%

30%

30%

30%

30%

30%

Line/MS

15%

15%

25%

30%

30%

30%

Section/RS

10%

30%

30%

30%

30%

30%