beautypg.com

Parameters, Table – EXFO FTB/IQS-88000 Series Power Blazer for FTB-2/2Pro/500/IQS-600 User Manual

Page 135

background image

Test Setup - Test Configurator, Timer, and System

Power Blazer

123

EtherSAM - Burst

Parameters

Number of Burst Sequence is the number of times, 1 to 100 (default is
2), the burst sequence will be repeated for the CBS and EBS tests.

Refill Delay Ratio (%) is the percentage of time required to refill the
CBS/EBS token buckets. The refill delay ratio is used for post-burst
delay and the remaining percentage is applied to the pre-burst delay.
The Refill Delay Ratio is configurable from 0 to 100% (50% is the
default as well as the standard’s minimum recommended value).

Burst/IR Frame Ratio (%) is the percentage of frames transmitted at
CIR rate for the CBS test and the percentage of frames transmitted at
CIR+EIR rate for the EBS test. The Burst/IR Frame Ratio is
configurable from 10 to 90% (90% is the default as well as the
standard’s recommended percentage value).

Table

Note: Test time values are only displayed for enabled services.

Service No indicates the service number.

Service Name indicates the name of the service.

Direction, available with Dual Test Set or Dual Port topology,
indicates respectively results from local to remote (L -> R) and remote
to local (R -> L), or P1 to P2 (P1->P2) and P2 to P1 (P2->P1).

CBS Test Time (s) indicates the total time required to perform all burst
sequence iterations of the CBS test for this service.

EBS Test Time (s) indicates the total time required to perform all burst
sequence iterations of the EBS test for this service.

Total Burst Test Time (s) indicates the total time required to perform
all burst sequence iterations of both CBS and EBS tests for this service.