Summary (s-oam and mpls-tp oam) – EXFO FTB/IQS-88000 Series Power Blazer for FTB-2/2Pro/500/IQS-600 User Manual
Page 395

Test Results
Power Blazer
383
Summary (S-OAM and MPLS-TP OAM)
Summary (S-OAM and MPLS-TP OAM)
From the Test menu, tap Results, and the Summary tab.
Test Status displays the current status of the S-OAM / MPLS-TP OAM
test. The global test pass/fail verdict is displayed next to the Test Status
when enabled (see Pass/Fail Verdict on page 237).
Start Time Indicates the date and time the test has been started. The
date and time is reset every time the test is restarted or reset.
Test/Power Recovery: Test Recovery (Widows 8 or above) or
Power Recovery (Windows XP), when displayed, indicates that the
test has automatically recovered from a power failure. The number of
occurrences is also displayed next to the Test/Power Recovery field.
Refer to Power Failure Recovery on page 521.
Logger Full, when displayed, indicates that the logger is full. Refer to
Logger on page 328.
Test Status
Description
--
The test is not running or results are not available.
In Progress
The test is running.
Completed
The test is completed, stopped at the planned time, or manually stopped when there is no
set timer.
Aborted
The test is interrupted; stopped before the set timer.