background image

Test Results

Power Blazer

355

Service Performance

Service Performance

From the Test menu, tap Results, and the Service Performance tab.

Service Name and Selection

Service Name indicates the name of the selected service.

Select the service to be displayed by either using the left/right arrow or by
tapping over the service numbers area then tapping on a specific service
number. An orange background indicates the selected service while a
green background indicates the services that are enabled.

SLA Parameters

The configured CIR, Max Jitter, Frame Loss and Max Latency/Max
Round-Trip Latency
SLA parameters are displayed. Refer to Services -
Profile
on page 192 for more infor
mation. For Dual Test Set or Dual Port
topology , parameters are displayed respectively for both local to remote (L
-> R
), remote to local (R -> L) directions, or P1 to P2 (P1->P2) and P2 to
P1 (P2->P1).

Metrics

Current, Average, Minimum, Maximum, and Estimate (Jitter) measured
values for each metric are reported. Direction, available with Dual Test
Set
or Dual Port topology indicates respectively results from local to
remote (L -> R) and remote to local (R -> L), P1 to P2 (P1->P2) and P2 to
P1 (P2->P1), and Round-Trip for Latency when in Round-Trip Latency
Measurement Mode (see Global Options on page 127). For Dual Test Set,
results for remote to local are obtained at the end of each step.

RX Rate indicates the measured utilization throughput.

Jitter (ms) indicates the measured delay variation.

Latency (ms) indicates the measured round-trip latency (delay).