Test Setup - Test Configurator, Timer, and System

Power Blazer

117

EtherBERT, FC BERT, and Unframed BERT

TX Pattern/RX Pattern: Select the test pattern from the list for each
direction (TX and RX) if required. Choices are PRBS9, PRBS11,
PRBS15, PRBS20, PRBS23, PRBS31 (default), Seed A

1

, Seed B

1

,

PRBS31 Unscrambled

1

, CSPAT

2

, CJTPAT

2

, CRPAT

2

, Short CRTPAT

2

,

Long CRTPAT

2

, and User Pattern.

When User Pattern is selected, enter the payload pattern hexadecimal
value.

Invert check box, when selected (cleared by default), inverts the
generated/expected test pattern meaning that every 0 will be changed
for 1 and every 1 for 0. For example, the pattern 1100 will be sent as
0011.

Bit/Pattern Error

The configuration of Bit Error is available with all patterns at the exception
of Seed A and Seed B for which Pattern Error is available.

Pass/Fail Verdict allows to enable and configure bit/pattern error
rate/count threshold prior to run the test. This allows for a simple
pass/fail verdict, leaving no room for misinterpretation of the test
results. To enable the pass/fail verdict, select either
Bit/Pattern Error Count or Bit/Pattern Error Rate (default is
Disabled).

BER Threshold allows to enter the threshold Count or Rate value that
will be used to declare the pass/fail verdict.

For Count, enter the maximum bit/pattern error count allowed before
declaring a fail verdict: 0 (default) to 999999.

For Rate, enter the maximum bit/pattern error rate allowed before
declaring a fail verdict: 1.0E-14 to 1.9E-01. The default value is 1.0E-12.

1. Only available for 10G LAN with Unframed without Sync (see Framing on page 91).
2. Only available for 1G optical with Framed Layer 1 (see Framing on page 91).