beautypg.com

3 getting started, Equipment rules for 88100nge/88100g, 3getting started – EXFO FTB/IQS-88000 Series Power Blazer for FTB-2/2Pro/500/IQS-600 User Manual

Page 19

background image

Power Blazer

7

3

Getting Started

If the FTB/IQS-88000 Power Blazer Series has been purchased at the same
time as the platform, the FTB/IQS-88000 Series module is pre-installed with
the appropriate software version.

Equipment Rules for 88100NGE/88100G

There is a limitation on the number of FTB/IQS-88100NGE/88100G modules
and Transport and Datacom modules that can run simultaneously on a
FTB-500 and IQS-600 platforms due to 40G/100G CFP power consumption,
the following equipping rules are mandatory. For example with a 8-slot
FTB-500 platform, two 88xx modules can run simultaneously with either
three 8105, one 8510B, or one 8510G.

Platform

Qty

a

a.

Number of FTB/IQS-88100NGE/88100G that can run simultaneously.

Run simultaneously with either...

b

b.

Each number represents the quantity of this module that can run simultaneously with the specified

number of FTB/IQS-88100NGE/88100G module without any other module. However these maximum

numbers are affected when mixing different modules.

88100NGE
88100G

8105
8805

8120NGE 8130NGE 8140 8525 8535 8510B 8510G 85100G 8830NGE

8830NGE-
16X

FTB-500
(4 slots)

1

1

0

0

0

0

0

0

0

0

0

FTB-500
(8 slots)

1

6

3

2

1

3

2

5

4

1

3

2

3

0

0

0

0

0

1

1

0

0

IQS-605P-HS

1

3

2

1

0

1

1

3

3

0

2

2

0

0

0

0

0

0

0

0

0

0

IQS-610P-HS

1

8

4

4

1

4

4

8

6

1

5

2

6

3

3

1

3

3

6

4

1

3

3

4

2

1

0

2

1

4

2

0

2

4

0

0

0

0

0

0

0

0

0

0