beautypg.com

Winco DGC-2020 User Manual

Page 295

background image

9400200990 Rev K

DGC-2020 Modbus

Communication

B-19

Holding

Register

Parameter Range

Read/Write

Supported

Data

Format

Units

40468 Override

Speed

Point7

0 to 8031.875
rpm

R

Raw ECU Parameter Data
0.125 rpm/bit, 0 rpm offset

40469

Override Time Limit

0 s to 25 s

R

Raw ECU Parameter Data
0.1 s/bit gain, 0 s offset

40470

Speed Lower Limit

0 to 2500 rpm

R

Raw ECU Parameter Data
10 rpm/bit gain, 0 rpm offset

40471

Speed Upper Limit

0 to 2500 rpm

R

Raw ECU Parameter Data
10 rpm/bit gain, 0 rpm offset

40472

Torque Lower Limit

0 to 125%

R

Raw ECU Parameter Data
1%/bit gain, -125% offset

40473

Torque Upper Limit

0 to 125%

R

Raw ECU Parameter Data
1%/bit gain, -125% offset

40474 Crankcase

Pressure

-250 to +251.99
kPa

R

Raw ECU Parameter Data
0.0078125 kPa/bit gain,
-250 kPa offset

40475

Oil Filter Diff. Pressure

0 to 125 kPa

R

Raw ECU Parameter Data
0.5 kPa/bit gain, 0 offset

40476

Fuel Filter Diff. Pressure

0 to 500 kPa

R

Raw ECU Parameter Data
2 kPa/bit gain, 0 offset

40477-82 FUTURE

USE

40493-99 FUTURE

USE

40500

DGC-2020 product series identifier

2020

R


40501

Firmware Part Number - 2nd most
significant digit. NOTE: The most
significant digit is always 9, but is
not mapped.

0 - 9

R

40502

Firmware Part Number - 3rd-6th
most significant digits

0000 - 9999

R

40503

Firmware Part Number - four least
significant digits

0000 - 9999

R

40504 LED

Status

individual bits
are 0 or 1

R

Bits indicate status of LED’s:
b0 = RUN
b1 = OFF
b2 = AUTO
b3 = ALARM
b4 = LOAD
b5 = NOT IN AUTO

40507

Read Relay Image of both Main
and Aux Output
(Duplicate of 40298)

individual bits
are 0 or 1

R

Main is in lower byte and Aux is in
upper byte.
b0 = Aux Output 1,
b1 = Aux Output 2,
b2 = Aux Output 3,
b3 = Aux Output 4,
b4 = Aux Output 5,
b5 = Aux Output 6,
b6 = Aux Output 7,
b7 = Aux Output 8.
b8 = Master Start Relay,
b9 = Fuel Solenoid Relay,
b10 = PreHeat PreLube Relay,
b11 = Alarm Relay,
b12 = UNASSIGNED,
b13 = Buzzer On,
b14 = EPS Loaded Relay,
b15 = PreAlarm Relay,

40508

Input Contacts States
(Duplicate of 40273)

individual bits
are 0 or 1

R

b0 = coolant level,
b1 = ATS,
b2 = E-stop,
b3 = charger failed,
b4 = aux. input 1,
b5 = aux. input 2,
b6 = aux. input 3,
b7 = aux. input 4.

/* b7 =