A
Auto Transfer Switch Input: Select Input (None, 1-16) and Contact Recognition (Always or While
Engine Running Only).
B
Grounded Delta Override: Select Input (None, 1-16) and Contact Recognition (Always or While Engine
Running Only).
C
Battle Override: Select Input (None, 1-16) and Contact Recognition (Always or While Engine Running
Only).
D
Low Line Override: Select Input (None, 1-16) and Contact Recognition (Always or While Engine
Running Only).
E
Single Phase Override: Select Input (None, 1-16) and Contact Recognition (Always or While Engine
Running Only).
F
Single Phase AC Override: Select Input (None, 1-16) and Contact Recognition (Always or While Engine
Running Only).
G
Battery Charger Fail: Select Input (None, 1-16), Alarm Configuration (None, Alarm, Pre-Alarm),
Activation Delay (s) (0 to 300 in increments of 1), and Contact Recognition (Always or While Engine
Running Only).
H
Low Coolant Level: Select Input (None, 1-16), Alarm Configuration (None, Alarm, Pre-Alarm),
Activation Delay (s) (0 to 300 in increments of 1), and Contact Recognition (Always or While Engine
Running Only).
I
Fuel Leak Detect: Select Input (None, 1-16), Alarm Configuration (None, Alarm, Pre-Alarm), Activation
Delay (s) (0 to 300 in increments of 1), and Contact Recognition (Always or While Engine Running Only).
Remote LSM Inputs
An optional LSM-2020 (Load Share Module) provides one configurable
A
contact input that can be used as
a setpoint source for Var, PF, or kW control. Settings are provided for min and max input voltage
B
, and
min and max input current
C
. Refer to Bias Control Settings in this section for information selecting the
LSM-2020 input as a setpoint source.
BESTCOMSPlus settings for the remote LSM input (DGC-2020, Programmable Inputs, Remote LSM
Inputs) are illustrated in Figure 4-29.