Standard mounting bracket (op-84259), Standard mounting bracket (op-84259) -20, Assembling the mounting brackets (sl-vfm/vhm/vlm) – KEYENCE SL-V Series User Manual
Page 96: Danger
3-20
In
3
SL-V-M-NO3-E
3-7
Assembling the Mounting Brackets (SL-VFM/VHM/VLM)
The installation holes for screws on mounting brackets for the SL-V are slot-shaped so that
they are larger than the actual screw size with which they are intended to be used. This
additional space can be used to adjust the position in which the device is installed. For this
reason, the proper installation of the device should be verified according to the procedure
outlined in "Regular (periodical) inspection" (page A-10) in the event that maintenance
requires the removal of the device from its target equipment or the adjustment of its
installation position after its initial installation onto that target equipment. Failure to follow this
installation instruction results in a significant harm to the machine operators, including serious
injury or death.
1
Install the base bracket as shown in the figure below and secure it with four of the included screws.
2
Install the mounting bracket as shown in the figure below and secure it with three of the included screws.
There are three types of mounting directions.
Danger
Standard mounting bracket (OP-84259)
Detection
surface
Base bracket
Hexagon socket bolts
(M5, Length: 6 mm, width across flat: 3 mm)
Recommended tightening torque: 6.8 N•m
Hexagon socket bolts
(M5, Length: 12 mm, width across flat: 4 mm)
L-shaped mounting bracket
Detection surface
Back mounting
Detection surface
Side mounting
Detection surface
45
o
mounting
Recommended tightening torque: 6.8 N•m