KEYENCE SJ-F036 User Manual
Instruction manual, Preface, Safety precautions
1
Before using this Built-in-Controller Type Static
Elimination Blower, be sure to thoroughly read this
Instruction Manual.
After you are finished with this Instruction Manual,
be sure to store it in a safe place for quick reference.
High-speed, High-precision
Built-in-Controller Type
Static Elimination Blower
Instruction Manual
96M00225
Preface
This document describes handling, method of operation and precautions when using the High-speed,
High-precision Built-in-Controller Type Static Elimination Blower SJ-F031/036. Before you start to use
the SJ-F031/036, be sure to thoroughly read this document in order to make full use and safely use the
functions of the SJ-F031/036.
Store this document in a safe place so that you can retrieve it whenever necessary.
■ Symbols
This manual uses the following symbols to alert you to important information.
Be sure to read below.
Failure to follow these instructions may lead to death or serious injury.
Failure to follow these instructions may lead to injury.
Failure to follow these instructions may lead to physical damage (product
malfunction, etc.).
Provides additional information on precautions and restrictions that must be
followed in operation.
Provides additional information on proper operation.
Indicates useful information or information that aids understanding of text descriptions.
Indicates a reference item or page to be referred to in this manual and a separate manual.
DANGER
WARNING
CAUTION
Important
Note
Tip
Safety Precautions
■
General Precautions
• At startup and during operation, be sure to monitor the functions and
performance of the SJ-F031/036.
• We recommend that you take substantial safety measures to avoid any
damage in the event that a problem occurs.
• Do not modify the SJ-F031/036 or use it in any way other than described in
the specifications. The functions and performance of products used or
modified in this way cannot be assured.
• When the SJ-F031/036 is used in combination with other instruments,
functions and performance may be degraded, depending on operating
conditions and the surrounding environment.
• Do not use the SJ-F031/036 for the purpose of protecting the human body.
■
SJ-F031/036 Handling Precautions
The SJ-F031/036 is a high-voltage product that is not designed in an explosion-proof structure. Pay
attention to the following when using the SJ-F031/036.
• To prevent electric shock and to ensure accurate static elimination, be sure
to connect a Class D ground (maximum resistance of 100 Ohms).
• Do not use this product in locations where there is the risk of ignition or
explosion from flammable solvents or dirt and dust.
• High voltage is applied to this product. Prevent it from being splashed with
water, oil, or flammable solvents. Failure to do so may cause insulation
breakdown, which will result in electric shock or malfunction.
• Do not bring your fingers or tools, wire or other metallic objects near this
product. Doing so may cause electric shock or malfunction.
• Do not use this product in a non-ventilated location. The ozone generated
from this product may become toxic. Be sure to ventilate the installation site
when this product is used in a non-ventilated location.
• Do not use this product in locations where sudden changes in temperature
or condensation are likely to occur. Doing so may cause accidents or
malfunction.
• Do not operate this product with wet hands. Doing so may cause electric
shock.
• Before starting maintenance, be sure to turn the power OFF. Failure to do so
may result in electric shock or accidents.
• During maintenance, do not directly touch the electrode needles. Doing so
may cause personal injury.
• If any malfunction is observed in this product, immediately turn it OFF, and
contact your nearest agent. You should never repair this product yourself.
Doing so may cause electric shock or malfunction.
Do not touch the electrode needles with a tool or other hard object. Damage to
the electrode needles will prevent static elimination performance from being
fully demonstrated, and cause accidents or malfunction.
CAUTION
WARNING
CAUTION
• When this product is used for a long period of time, the electrode needles
become dirty due to the adhesion of dust and dirt. If the ion level alarm
indicator or condition alarm indicator blinks in red clean the electrode
needles. If the electrode needles are used in a dirty or dusty state, the static
elimination performance can no longer be fully demonstrated, resulting in
accidents or malfunction. We recommend periodically cleaning the
electrode needles (as a guideline, once every two weeks in a regular
operating environment though this depends on the installation conditions).
• Do not drop or subject this product to shock. Doing so may result in
accidents or malfunction.
• Use this product for static elimination only. Do not use it for other purposes.
■
Power Supply Precautions
• Use a DC power supply with rated 24 V output.
• Noise applied to the power supply may cause this product to malfunction. If
this happens, install an insulated transformer.
• When using a switching regulator, be sure to connect a Class D ground to
the Frame Ground terminal.
■
Grounding Precautions
• To ensure safety and appropriate static elimination, be sure to ground this
product.
• Be sure to connect a Class D ground (maximum resistance of 100 Ohms).
■
SJ-F031/036 Warning Label
A WARNING label is affixed on the SJ-F031/036 to ensure safety.
Read the description on this WARNING label to ensure correct use of the SJ-F031/036.
CAUTION
CAUTION
CAUTION
Be sure to turn the power off when replacing
the electrode probes. Otherwise, electric shock may occur.
Do not touch electrode probes with your hands
or fingers, as this may cause injury.
WARNING
START
/STOP
BALANCE
ION
FAN
COND
IONLEVEL
1
1
* WARNING labels in Japanese, German, French, Italian and Chinese:
SC are provided.
Use them as necessary.
Document Outline
- Preface
- Safety Precautions
- Precautions on Regulations and Standards
- 1-1 System Configuration
- 1-2 Checking the Contents of the Package
- 1-3 Names and Functions of Parts
- 2-1 Before Installation
- 2-2 Connection and Installation
- 3-1 Operation
- 3-2 About Display Function
- 4-1 About Maintenance
- 4-2 Performing Maintenance on the Electrode Needles
- 4-3 Performing Maintenance on the Air Filter
- 5-1 Timing Charts
- 5-2 Specifications
- 5-3 External Dimensions
- 6-1 Troubleshooting
- 6-2 Table of Indicated States