Temporary Suspension of Safety Function
2-43
2
SL-V-M-NO2-E
Changing of the condition for termination of muting (maximum muting period)
(1) Follow the procedure under "Entering the password".
"Entering the password" (page 2-39)
(2) This setting depends on the state of the override input (red/black wire on the receiver).
ON: The condition for termination of muting (maximum muting period of approx. 5 minutes) is deac-
tivated, which means that no defined maximum muting period is active. (the interlock indicator on
the receiver blinks.)
OFF: The condition for termination of muting (maximum muting period of approx. 5 minutes) is acti-
vated, which means the default period is active. (the interlock indicator on the receiver does not
light.)
(3) Turn ON the muting input 1.
(4) Turn ON the muting input 2, and then turn OFF the muting input 2. You must repeat this action three
times. The LED 1 and LED 2 on the bar LED on the receiver light in green.
(5) Turn OFF the muting input 1.
(6) Turn ON the muting input 2.
(7) Turn ON the muting input 1, and then turn OFF the muting input 1. You must repeat this action four
times. The bar LED 3 on the receiver lights in red.
(8) Turn OFF the muting input 2.
(9) If these procedures are performed correctly, the LED 1 and LED 2 on the bar LED on the receiver
light in green. Afterwards, the center indicator on the receiver lights in red and then lights in green
again approximately one second later. This indicates that the settings are completed.
(10) Turn OFF the power to the SL-V, and then the interlock mode selection input (pink wire from the
transmitter) must be wired.
"Interlock Function" (page 2-7)
(11) The condition for initiation of muting (time period between muting input 1 and 2) is changed when
the power to the SL-V is turned ON. The SL-V keeps this condition even if the power to the SL-V is
turned OFF.
When another condition for muting, regardless of initiation or termination, is also changed in addition to the
change of the above-mentioned condition, you can continue the procedure for another condition following
the step (9).
On the other hand, when the change of the above-mentioned condition follows the change of another con-
dition for muting, regardless of initiation or termination, you can waive the step (1).
Ex.: Time chart when the maximum muting period (default) is deactivated
Reference
Override input
From here on, the override
input can be either on or off
ON
OFF
Muting input 1
ON
OFF
Muting input 2
ON
OFF
ON
OFF
SL-V
P
erf
or
m "Enter
ing the pass
w
ord"
B
2 s or more
B
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A: 20 ms or more, B: 40 ms or more
(2)
(3)
(4)
(5)
(7)
(10)
(1)
(6)
(8)
Cable
Self-diagnosis
Series Connection
Interlock
AUX
EDM
Wait
State Information
Alert
Clear/Blocked
Suspension
Fixed
Reduced
Monitoring