KEYENCE SL-V Series User Manual
Page 61
2-11
Temporary Suspension of Safety Function
2-37
2
SL-V-M-NO2-E
(11) Turn OFF the muting input 1.
(12) For the number of 3rd digit to 1st of password, perform the same procedure of (9) to (11).
If these procedures are performed correctly, the function indicators (excluding the interlock indicator) on
the receiver blink slowly. If the password is incorrect, the SL-V goes back to the I/O monitoring mode.
(13) Turn ON the muting input 1.
(14) Turn ON the muting input 2, and then turn OFF the muting input 2. You must repeat this action nine
times.
(15) Turn OFF the muting input 1.
(16) Turn ON the muting input 2.
(17) Turn ON the muting input 1, and then turn OFF the muting input 1. You must repeat this action four
times.
(18) Turn OFF the muting input 2. If these procedures are performed correctly, the center indicator on
receiver lights in green.
Afterwards, you can set the new password digit-by-digit in the following order: 4th, 3rd, 2nd and 1st. You
can confirm which the digit is selected through the blinking status of function indicators on the receiver.
(19) Turn ON the muting input 1.
(20) Turn ON the muting input 2, and then turn OFF the muting input 2. You must repeat this action with
the same number of times as the number of 4th digit of password. While you repeat this action, the
bar LEDs on transmitter and receiver light in green corresponding to the number of that action as
shown in step (10).
If you repeat this action 10 times, the number returns to "0".
(21) Turn OFF the muting input 1.
(22) For the number of 3rd digit to 1st of password, perform the same procedure of (9) to (11).
(23) When the step (22) is completed (this means all digits have been set.), the function indicators
(excluding the interlock indicator) on the receiver blink slowly.
Number
5
6
7
8
9
Bar LED
5
4
3
2
1
5
4
3
2
1
5
4
3
2
1
5
4
3
2
1
5
4
3
2
1
Cable
Self-diagnosis
Series Connection
Interlock
AUX
EDM
Wait
State Information
Alert
Clear/Blocked
Suspension
Fixed
Reduced
Monitoring