KEYENCE SJ-F5000 Series User Manual
Instruction manual, Precautions on regulations and standards
1
High-speed, High precision, Wide Static
Elimination Blower
SJ-F2000/5000 Series
Instruction Manual
Read this instruction manual before using the product in order to achieve maximum performance.
Keep this instruction manual in a safe place after reading it so that it can be used at any time.
Symbols
The following symbols alert you to important messages. Be sure to read these messages
carefully.
Indicates the reference pages in this manual or the reference pages in separate manuals.
Safety Information on SJ-F2000/5000 Series
General precautions
Precautions on power supply
Precautions specific to the SJ-F2000/5000 Series
Locations
Other precautions
Precautions on Regulations and Standards
CE Marking
Keyence corporation has confirmed that SJ-F2000/5000 series complies with the essential
requirements of the applicable EC Directives, based on the following specifications. Be sure to
consider the following specifications when using SJ-F2000/5000 series in the Member States of
European Union.
z
EMC Directive
• Applicable Standard EMI : EN61326-1, ClassA
EMS : EN61326-1
• The length of all input/output cables must be less than or equal to 30m.
Remarks:
These specifications do not give any guarantee that the end-product with this product
incorporated complies with the essential requirements of EMC Directive. The manufacturer
of the end-product is solely responsible for the compliance on the end-product itself
according to EMC Directive.
z
Low-Voltage Directive
• Applicable Standard EN61010-1
• When using the AC adapter applicable to SJ-F2500/SJ-F2000, use the AC adapter
(SJ-U1/SJ-U2) specified by KEYENCE.
• SJ-F5000/SJ-F5500 is designed as a Class I equipment. Be sure to connect the protective
earthing terminal on the AC power cable to the protective earthing conductor in the
building installation.
• Use this product at the altitude of 2000 m or less.
• Indoor use only.
CSA Certificate
SJ-F2000/5000 series complies with the following CSA and UL standards and has been certified
by CSA (Class 2252 05/Class 2252 85). Be sure to consider the following specifications when
using this product as a product certified by CSA.
• Applicable standard: CAN/CSA C22.2 No.61010-1
UL61010-1
• When using the AC adapter applicable to SJ-F2500/SJ-F2000, use the AC adapter
(SJ-U1/SJ-U2) specified by KEYENCE.
• SJ-F5000/SJ-F5500 is designed as a Class I equipment. Be sure to connect the protective
earthing terminal on the AC power cable to the protective earthing conductor in the
building installation.
• Use this product at the altitude of 2000 m or less.
• Indoor use only.
• When using SJ-F2010/SJ-F5010, use the following power supply.
CSA/UL-listed power supply that provides Class 2 output as defined in the CEC
(Canadian Electrical Code) and NEC (National Electrical Code), or CSA/UL-listed power
supply that has been evaluated as a Limited Power Source as defined in CAN/CSA-C22.2
No. 60950-1/UL60950-1
It indicates a hazardous situation which, if not avoided, will result in death or
serious injury.
It indicates a hazardous situation which, if not avoided, could result in death
or serious injury.
It indicates a hazardous situation which, if not avoided, could result in minor
or moderate injury.
It indicates a situation which, if not avoided, could result in product damage
as well as property damage.
It indicates cautions and limitations that must be followed during operation.
It indicates additional information on proper operation.
It indicates tips for better understanding or useful information.
• Do not use this product for the purpose to protect a human body or a part
of human body.
• This product is not intended for use as explosion-proof product. Do not
use this product in a hazardous location and / or potentially explosive
atmosphere.
• You must verify that the SJ-F2000/5000 Series is operating correctly in
terms of functionality and performance before the start and during the
operation of the SJ-F2000/5000 series.
• We recommend that you take substantial safety measures to avoid any
damage in the event of a problem occurring.
• KEYENCE never warrants the function or performance of the SJ-F2000/
5000 Series if it is used in a manner that differs from the SJ-F2000/5000
Series specifications contained in this instruction manual or if the
SJ-F2000/5000 Series is modified.
• When the SJ-F2000/5000 Series is used in combination with other
instruments, functions and performance maybe degraded, depending on
operating conditions and the surrounding environment.
• Use the power supply with the specified rated voltage and current.
• Do not connect multiple power supplies to a single SJ-F2000/5000 Series
or more than one SJ-F2000/5000 Series connected together, otherwise the
power supplies will be short-circuited , which may result in accidents or
product malfunction.
• Noise conveyed through the power supply line may cause the SJ-F2000/
5000 Series to malfunction. Be sure to use a stabilized DC power supply
with an insulated transformer.
• When using a commercially available switching regulator, be sure to
completely ground the switching regulator's frame ground terminal.
When the SJ-F2000/5000 Series is used in an enclosed space, the generated
ozone may become harmful. Make sure that there is adequate ventilation.
• The appropriate AC power cable for SJ-F5000/SJ-F5500 must be provided
by the user, which complies with the technical regulation and/or standard
in the countries and/or regions for use.
• To avoid the risk of electric shock or product malfunctions, prevent water,
oil, or flammable solvent from splashing onto the SJ-F2000/5000 Series.
• To avoid the risk of injury, electric shock, or product malfunctions, keep
fingers and metallic objects such as tools or wires away from the
SJ-F2000/5000 Series during operation.
• To avoid the risk of electric shock, do not operate the SJ-F2000/5000 Series
with wet hands.
• To avoid the risk of electric shock or product malfunctions, be sure to turn
the power off during maintenance of the SJ-F2000/5000 Series.
• To avoid the risk of injury, do not touch the electrode probes directly with
your hands or fingers during maintenance.
• If any abnormality is observed in the SJ-F2000/5000 Series, immediately
turn off the power and contact the nearest KEYENCE office. Do not try to
repair the SJ-F2000/5000 Series by yourself. This may cause electric shock
or product malfunctions.
• Do not use this unit for any purpose other than eliminating static.
DANGER
WARNING
CAUTION
NOTICE
Important
Point
Reference
WARNING
CAUTION
NOTICE
CAUTION
NOTICE
WARNING
CAUTION
• For proper static elimination, be sure to ground the functional grounding
terminal of the SJ-F2000/5000 Series at a resistance not exceeding 100 Ω.
• Do not use the SJ-F2000/5000 Series in a location in which the temperature
changes suddenly, or where condensation occurs. This may lead to
product breakdown.
• Do not touch the SJ-F2000/5000 Series' electrode probes with hard objects
such as tools. If the electrode probes are damaged, the SJ-F2000/5000
Series does not operate properly, resulting in product malfunctions.
• When the SJ-F2000/5000 Series is used over a long time, dust accumulates
on the electrode probes. Clean the electrode probes when the alarm
indicator flashes. If you continue to use the SJ-F2000/5000 Series with dust
accumulating on the electrode probes, the SJ-F2000/5000 Series will not
operate properly, resulting in product malfunctions. Regular cleaning is
recommended.
• Do not drop the SJ-F2000/5000 Series or subject it to a strong impact. This
may cause product malfunctions.
To prevent product malfunctions, avoid installing the SJ-F2000/5000 Series in
the following locations.
• Locations in which the SJ-F2000/5000 Series may be directly subjected to
vibration or impact.
• Locations in which the ambient temperature drops below 0°C or exceeds +
50°C.
• Locations in which the relative humidity drops below 35% or exceeds 65%,
or where condensation occurs.
• Locations in which the temperature changes suddenly.
• Locations in which the SJ-F2000/5000 Series is exposed to a direct breeze
from an air conditioner.
• Locations in which there are volatile or flammable substances, solvents, or
corrosive gases.
• Locations exposed to dust, salt, metal particles, or greasy fumes.
• Locations in which water, oil or chemicals may splash onto the SJ-F2000/
5000 Series.
• Locations in which a strong magnetic or electric field is generated.
Be sure to follow all procedures described in each section of this instruction
manual.
This SJ-F2000/5000 Series uses EEPROM. Do not power off the unit while it
is being set.
NOTICE
CAUTION
WARNING
NOTICE
96M11352
Document Outline
- Safety Information on SJ-F2000/5000 Series
- Precautions on Regulations and Standards
- Getting Started
- Installation and Connection
- Operation and Function
- Power on
- Start/stop static elimination
- External interruption of static elimination (SJ-F2010/5010 only)
- Control the airflow
- Electric charge level display function
- Alarm output/display function
- Initialization
- Keylock function
- Output verification (SJ-F2010/5010 only)
- NPN/PNP output switching (SJ-F2010/5010 only)
- Maintenance of Electrode Probes
- Timing Charts
- Warnings and Remedies
- External Dimensions
- Specifications