beautypg.com

5 aux (auxiliary) output, Aux (auxiliary) output -14, Aux (auxiliary) output – KEYENCE SL-V Series User Manual

Page 38: Danger, Wiring, Time chart

background image

2-14

Fu
nct
ion
s and

Feat

ures

2

SL-V-M-NO2-E

2-5

AUX (Auxiliary) Output

The AUX (Auxiliary) output is a NON-SAFETY-RELATED function.
This output just informs an external device (non safety-related device) of the operations of the SL-V and

operates in synchronization with OSSD operation. It can only be connected to a PLC or similar non-safety
devices.

The AUX output is not allowed to be used as a safety output for safety-related control
systems. This output does not constitute a part of the safety-related control system. Usage
of this function as a safety output may result in significant harm to the machine operators
including injury or death.

Wiring

Output rating : 26.4 V DC or less, 50 mA or less

Regardless of if you are using an NPN or a PNP cable, the SL-V AUX output can be connected to PNP

and NPN devices. Refer to the time charts mentioned in this manual because the AUX output logic is dif-

ferent depending on the connected device.

Time chart

(1) When using a PNP output cable to connect to a PNP input device,

or when using an NPN output cable to connect to an NPN input device

(2) When using a PNP output cable to connect to an NPN input device,

or when using an NPN output cable to connect to a PNP input device

Danger

Input device

Brown

Red(AUX output)

Blue

0V

+24V

Trans-

mitter

Main

circuit

0V

+24V

Trans-

mitter

Main

circuit

Brown

Red(AUX output)

Blue

Input device

For connecting a PNP input device

For connecting an NPN input device

NOTE

50 ms max.

50 ms max.

(1)

ON

OFF

(2)

ON

OFF

ON

OFF

OSSD

AUX