beautypg.com

1 bar led indicator, Upon power-up, Bar led indicator -2 – KEYENCE SL-V Series User Manual

Page 120: Upon power-up -2, Bar led indicator

background image

6-2

In

di

ca

tors

6

SL-V-M-NO6-E

6-1

Bar LED Indicator

The bar LEDs 1 to 4 light up in the following sequence during start-up (approx. 4.5 s). The other indica-
tors will remain off. The indicator sequence will be identical on both the transmitter and receiver.

The OSSD and the muting lamp outputs will remain OFF during power-up. The states of the other outputs

will depend on how the external devices are connected. With exception for the OSSD output, Keyence

recommends that all outputs of the SL-V series be deactivated from the control system during power-up.

LEVEL

WAIT

OSSD

FUNCTION

INTER
LOCK

ø25 (0.98")

SL-V08H

1

2

3

4

5

Bar LED indicator

Function indicator

Transmitter

LEVEL

MUTE1

MUTE2

OSSD

INTER
LOCK

ø25 (0.98")

SL-V08H

1

2

3

4

5

Receiver

Bar LED indicator

Function indicator

Indicator color

Red or green

Red or green

Red or green

Red or green

Red or green

Orange

Orange

Red or green

Yellow

Upon power-up

Bar LED
indicator

Output logic during startup

When connected to a PNP

input device

ON

When connected to an NPN

input device

OFF

OFF

5

OFF

4

3

2

Red

1

OFF

OFF

OFF

5

OFF

4

3

Red

2

Red

1

OFF

OFF

5

OFF

4

Red

3

Red

2

Red

1

OFF

5

4

Red

3

2

Red

1

Red

Red

NOTE